今天我们来研究下 飞利浦磁共振不打药全心冠状动脉成像 序列。 

今天我们来研究下 飞利浦磁共振不打药全心冠状动脉成像 序列。

91601635809599010 78791635809599319 cs3D_TFE_WH 3D TFE whole heart coronary scan

3D TFE 全心冠状动脉扫描

Free breathing single volume TFE coronary scan using Compressed Sense.

自由呼吸联合压缩感知 TFE 容积冠状动脉扫描。

Info:  信息:

A SPIR fat suppression is applied to enhance the contrast of the artery and the surrounding fat.

使用 SPIR 脂肪抑制,提升冠脉与周围脂肪的对比。

13631635809599448

A T2prep pulse is applied to further enhance the contrast between the arteries and the surrounding myocardium.

施加 T2 预准备脉冲,进一步提高冠脉与周围心肌的对比。

55291635809599626

Navigator gating and tracking is enabled to correct for respiratory motion. The scale factor for the feet-head correction is set to 0.45 according to Jahnke et al. J. Magn. Reson. Imaging 2007;26:780-786.

使用 gating and tracking 导航回波校正呼吸运动。根据文献 Jahnke et al. J. Magn. Reson. Imaging 2007;26:780-786,设置头足方向校正比例因子为 0.45。

38111635809599861

Trigger delay is set to mid-diastole. However it is advised to measure the precise delay using a high-temp cine scan.

心电触发延迟设置成舒张中期。 然而,建议使用高时间分辨率的电影扫描序列来精准地测量延迟时间。

24691635809600261

RF-shimming is enabled to reduce possible B1-inhomogeneities.

使用射频匀场,减少 B1 场不均匀性的可能性。

61071635809600648 97141635809600993

Tips:

建议:

The whole heart scan is a lengthy scan. For the best results it is very important to instruct the patient not to move during the scan.

全心扫描是很耗时间,为了获得最好的结果,指示病人在扫描时不要动很重要。

The navigator beam should be placed at the center of the dome of the right hemidiaphragm. For 2/3 into the liver. 

将导航条放在右膈膈顶,上三分之一在肺脏,下三分之二在肝脏。

94401635809601501

For the best results the trigger delay should be set to user defined. From the high temporal cine scan the moment that diastole starts (when heart stops moving) should be entered as trigger delay.

为了获得最好的结果,心电触发延迟时间需要设置成用户自定义。从高时间分辨率的电影扫描序列中找到舒张期的开始时刻(此时心脏停止跳动),此时刻即为触发延迟时间。

微信视频预览查看

23491635809602043

19941635809602900

The TFE shot duration (acquisition duration) on the contrast page should match the resting period of the heart in diastole. If the acquisition duration is longer, cardiac motion blurring could occur. The TFE factor is displayed on the info page.

对比选项卡中的 TFE shot duration(采集时间段)需与舒张期心脏静息时段相匹配。如果采集时间延长,就可能会由于心脏运动而产生模糊。TFE factor 大小会在信息栏中显示。

86441635809603186

The foldover direction should be choosen such that ghosting of the slightly moving anterior chest wall is avoided. That is preferably in feet-head or left-right direction. If using left-right foldover you should use oversampling such that all anatomy in left-right direction is covered.

选择相位编码方向时,应当避免前胸壁产生运动伪影。最好选择头足方向或左右方向。如果使用使用左右相位编码方向,那么应打开过采样将左右方向上的所有组织给覆盖。